R314LH-30-D43-QMA

Rack Mounted Attenuator (In-Line Connectors) Tray for DAS Solution

-161dBc, 50W, 1RU High, 600-4200MHz

R314LH-30-D43-QMA is a horizontally mounted Modular DAS Tray solution that can hold 2 Attenuator Modules on a 1RU High Rack or H-Frame. Each Attenuator Tray has 2 modules with 4x 30dB attenuators integrated in one housing, each having its own independent RF path. Each attenuator path can handle 50W of power and operates from 600MHz – 4200MHz. These attenuators are guaranteed for Low-PIM performance in the entire frequency range. The attenuator connectors are in an In-Line configuration for easy cable management with Input Connectors at the back and Output connectors at the front of the DAS Tray. Different connector configurations are available.

The 30dB Attenuators comes with 4.3-10 (F) connectors on the Input side and QMA (F) connectors on the Output side. For any other value of attenuation or connector combination, please refer to the PART NUMBER ORDERING INFO table.

FEATURES

  • 2 Attenuator Modules on 1RU tray
  • Each tray has a total of 8x Attn with
    each having an independent RF Path
    having a fixed attenuation value.
  • In-Line connector configuration with
    INPUT connectors at the back and
    OUTPUT connectors on the front
  • CBRS / C-Band Ready
  • Low PIM , -161dBc
  • In Stock to low lead time delivery

Electrical Specification

Attenuation
Value (XX)
2dB3dB5dB6dB8dB10dB15dB20dB30dB40dB
Attenuation
Accuracy
±0.25±0.50±0.50±0.50±0.75±1.00±1.00±1.00±1.25±1.50
No. of
Attenuators
8x per Tray (Independent RF Path)
Frequency
Range
600MHz - 4200MHz
Return Loss19 dB (Typ)
Intermodulation
(PIM - 3rd)
-161 dBc (Typ) (2 Tones +43 dBm)
Impedance 50 Ohms
Input Power50W (Average Power)
Temperature
Range
-30°C to 70°C
Weight 16 lbs
Connectors Different Connector Configurations available. Please see PART NUMBER ORDERING INFO table
Rack Space
Needed
1RU
Dimensions1.72”(H) x 18.88”(W) x 7.875”(D)

Mechanical Specifications

© Innowave RF, LLC. All Rights Reserved. Specs can change without notice. Drawings are for reference purpose only